11
3.2 Diagnostics Mode
To go to “diagnostics mode” turn on the machine is displayed.
Within the first 5 seconds, press the 8-9-8-2 keys in order to display
and then press OK to display
The programming menu is displayed.
Keys “2” and “3” are used to scroll through the settings.
Key “4” is used to change the settings and confirm.
Key “1” is used to quit diagnostics mode.
MACHINE SETTINGS SETTING RANGE FUNCTION
1
1 Large coffee – 520 impulses 50 – 800 Number of pump impulses to make a large coffee
2
1 Expresso – 170 impulses 50 – 800 Number of pump impulses to make an expresso coffee
3
1 Coffee – 290 impulses 50 – 800 Number of pump impulses to make a coffee
4
Hot Water – 260 impulses 50 - 800 Number of pump impulses to distribute hot water
5
Steam timer 20 seconds 5 - 120
6
K1 Setting K1 Value 8 1 – 50
K1 is the temperature rise factor. High value = high factor (do
not modify the selected value)
7
K2 Setting K2 Value 30 1 – 50
K2 is the influence of frequency of use on the temperature
setting. High value = low influence (do not modify the selected
value)
8
Normal temperature 90 °C 70 – 130 °C Normal temperature
9
High temperature 110 °C 70 – 130 °C High temperature
10
Temperature of the 1st coffee
117 °C
70 – 130 °C Temperature of the first coffee
11
Total grounds 0 0 – 50 Coffee grounds counter
12
Stop grounds 12 0 - 50 Limit beyond which the coffee grounds tray should be emptied
13
Total water 0 Boiler 1 total distributed water (not modifiable)
14
De-scaling water ml -- 0
When the set value is reached the “de-scale” message is
displayed (not modifiable)
15
Water filter ml --
Quantity of water filtered since the Aqua Prima filter was
activated
16
H2O after de-scaling message
ml --
0
Quantity of water used since the “de-scale” message was
displayed
17
Hot water flow l/h 20 06 - 26 Flow in l/h during hot water distribution
18
Hot water pump settings 62430
Pump settings for water distribution (do not modify the selected
value)
19
Water tank – number of
impulses 0
0 Water tank counter
20
Water tank stop – n° of impulses 750 Water tank stop
SELECT FUNCTION
MACHINE READY
Software
Programming
energy saving
Auto-diagnostic