EasyManua.ls Logo

DeDietrich DED700X - Checking Micro-switches and Sensors

DeDietrich DED700X
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
3.6 Checking micro-switches and sensors
Description Activated Deactivated Notes
1 Geared motor micro-
switch WORK
Distributor in WORK
position
Distributor not in
WORK position
2 Geared motor micro-
switch HOME
Distributor in HOME
position
Distributor not in
HOME position
3 Front command strip
micro-switch
Command strip closed Command strip
open
5 COFFEE GROUNDS TRAY
micro-switch
Tray present Tray absent
6 DISTRIBUTION GROUP
micro-switch
Present Absent
7 DOOR Micro-switch Door closed Door open
8 FLOW METER
The technician
can check the
impulses
9 COFFEE GRINDER
IMPULSES
The technician
can check the
impulses
0 WATER LEVEL in the
tank
Level is OK Level is LOW
A WATER ALARM micro-
switch
Water detected in the
bottom of the machine
No water detected
in the bottom of the
machine.
M Coffee holder empty There is no coffee There should be
coffee.
This is derived
and not
hardware data.
R CLOCK (shows seconds) Even seconds Odd seconds It should flash at
1 HZ
K FRONT FACE PRESENT Present Absent
0-8 COFFEE GRINDER
SETTINGS
Factory settings
* COFFEE GRINDER
SETTINGS SAVED
Not saved Saved