NI-267 index 1 June 2021
Assembly Cable / Cable gland
Reassembling the cover
Position the cover in the notch on the base. Fin in the alignment above.
Press the cover onto the base.
Lock by turning the cover clockwise until the fins of the cover and the base are aligned.
Pneumatic connexion
Sorio® Basic 1EV unit
EV: Solenoid valve
1: Actuator air inlet
E: Exhaust
P: Air pressure
ACT: Exhaust (actuator Normally Closed)
Or Air inlet (actuator Normally Open)
B
Cover fin
D
Cover fin
Base fin
Cover fin
Sensor
High Position
Sensor
Low Position
Terminal
block 1EV
N.C
Apply pressure to the channel [P].
For an actuator operating as N.C. (Normally closed),
connect the actuator to the channel [1] of the box as
shown opposite.
EV
E
1
ACT
P
N.O
Apply pressure to the channel [P].
For an actuator operating as N.O. (Normally open),
connect the channel [ACT] to the channel [1] of the
box and put a pierced plug on the actuator as shown
opposite.
Unscrew the nut [B] from the cable gland [C].
Pass the connection cable inside the nut, then the cable gland to connect it to
the terminal block [D].
Tighten the nut [B].
Connect the connections to the terminal block
P
1
Pierced
plug
1
P
ACT
B
D
C