DeLaval ALPRO ID Champion
Instruction Book
© DeLaval 2014. 85417601
2014-12-03, Version 5 Original instruction

Questions and Answers

  • I
    Ian MoodyAug 26, 2025
    Why is the power LED off on my DeLaval Farm Equipment IRW?
    • J
      Jermaine ShermanAug 26, 2025
      If the Power LED on the IRW (Identification Reader Wall) is off on your DeLaval Farm Equipment, the most likely cause is that the power supply is off. Check that 12 VAC is connected between pin 27 and 28.
  • C
    christine87Nov 3, 2025
    How to fix wrong ID or low hit rate on DeLaval Farm Equipment?
    • S
      Sylvia EdwardsNov 3, 2025
      If you're experiencing a wrong ID, missed ID, or a low hit rate with your DeLaval Farm Equipment, several factors could be the cause. It might be due to more than one cow being in front of the antenna, which can be resolved by narrowing or extending the lane in front of the antenna or using an archway to prevent cows from riding in the lane. Also, ensure that no steelwork is missing or deformed. Another potential issue could be malfunctioning transponders, which would require exchanging any broken or weak ones. Ensure the transponder is on the correct side. Check the photocell to make sure it's clean and correctly directed. If it's dirty, clean it. If misdirected, correct its direction so it reads the cow right in front of the antenna. You should also control the function of the photocell...
  • S
    Sarah LivingstonNov 10, 2025
    Why am I getting missed IDs when cows are entering with DeLaval Farm Equipment?
    • B
      Brittney CampbellNov 10, 2025
      If you are experiencing missed IDs when cows are entering with your DeLaval Farm Equipment, consider these potential causes and solutions: * **Interference:** Frequency converters, especially in rotary setups, can cause interference. Ensure you follow the assembly instructions for the frequency converter, use shielded wires, and consult with the supplier on effective interference suppression. A filter on the cable can help, and the frequency converter should be placed as far as possible from the antenna, avoiding installation in the same cable duct. * **Voltage Issues:** Verify that the input voltage is within the acceptable range of 12 VAC +20%, -10%. If it's below this, correct the voltage. * **External Disturbances:** Computer screens, mobile telephone chargers, or other electron...
  • S
    Shawn ObrienNov 18, 2025
    What to do if cow ID doesn't appear on MPC with DeLaval Farm Equipment?
    • K
      Krista MorganNov 18, 2025
      If the Cow ID is not appearing on the MPC when cows are entering the parlor using DeLaval Farm Equipment, it might be due to a communication problem. Check the ALCOM bus connection on the IRW. Ensure the Power LED is on and that the transponder activation LED on the IRW is flashing when cows are passing. Verify that the Portal ID is correctly configured in ALPRO. Also, confirm that the Gate switch connects pin 22 and 23 on the IRW connections when the entrance gate is open. Pin 22 is ground, and pin 23 should be between 12 to 15 VDC when the gate is closed. When the gate is open, the Gate switch should short circuit pin 22 and 23, resulting in 0 V on pin 23. If no Gate switch is installed, pin 22 and 23 should be short-circuited with a wire. For Rotary systems, ensure that the cow is det...

Summary

Safety Precautions

Warnings and Cautions

Defines danger, warning, caution, mandatory, and prohibited admonishments used in DeLaval documentation.

General Description

Important Issues Regarding Electronic ID

Discusses noise interference affecting electronic ID systems and transponders in the kHz range.

Operators Maintenance

Daily Maintenance Tasks

Outlines daily checks for the IRW antenna, photocell, and cable routings.

Troubleshooting Guide

Troubleshooting Common Issues

Provides a table of symptoms, causes, and actions for common system problems.

Missed ID When Cows Enter

Lists causes like interference, software, or broken antenna for missed IDs.

IRW Not Connected to ALPRO

Details checks for node status, ALCOM bus, and power for IRW connectivity.

IRW Power LED Off

Addresses issues related to the IRW's power supply and LED status.

Cow ID Not Appearing on MPC

Covers communication problems, power, and gate switch configurations for missing IDs.

Cow ID Erased from MPC

Suggests checking photocell detection and exit gate switch operation.

Antenna Tuning Problems

Explains LED indications for antenna inductance issues and potential causes.

DeLaval ALPRO ID Champion Specifications

General IconGeneral
CategoryFarm Equipment
TypeAutomatic Identification System
Product TypeAnimal Identification Reader
Identification TechnologyRFID (Radio Frequency Identification)
FunctionAnimal Identification and Data Collection
ApplicationDairy Farm Management
IntegrationIntegrated with DeLaval milking equipment and herd management systems

Related product manuals