V0802, 5.10
Parameter 17: RSD switch mounted
Range : 0 - 1
Default : 1
Units : -
Remark : Only in combination with the encoder position measurement system.
Function
RSD-switch mounted and used for reference search yes (1) or no (0).
Description
Two systems for reference search are implemented:
1. without reference search direction switch (program 0)
2. with a reference search direction switch (program 1)
Press the key to select the required setting.
System 1
The standard reference search system. For this system the motor drive must be equipped with a
direction sensitive enable/disable input.
System 2
The motordrive does not need any direction sensitive enable/disable input for reference search.
Also you are free where you place the reference search direction switch (RSD). It may be the
same switch; EOT-switch.
Figure 5.2.a