Delem
V1101, 9.14
Parameter PN: Proportional gain min
Range : 0 - 9999
Unit : -
Default : 0
Function
Gain of the reference input signal. This value is for the first setpoint of the speed/gain function.
Parameter PX: Proportional gain max
Range : 0 - 9999
Unit : -
Default : 0
Function
Gain of the reference input signal. This value is for the second setpoint of the speed/gain
function.