Delem
V1101, 3.123
Parameter 123-130: Sequencer options
Range : 0000 - 1111
Default : 0000
Units : -
Function
To set general purpose sequencer option flags.
Description
You can set 4 flags per sequencer option parameter. Each flag can have the value 0 or 1.
- sequencer option flags 4..1 123 = 0000
- sequencer option flags 8..5 124 = 0000
- sequencer option flags 12..9 125 = 0000
- sequencer option flags 16..13 126 = 0000
- sequencer option flags 20..17 127 = 0000
- sequencer option flags 24..21 128 = 0000
- sequencer option flags 28..25 129 = 0000
- sequencer option flags 32..29 130 = 0000
To set option flag 1 and 2 you should program parameter 123 as 0011. Pay attention that you
count from right to left. The lowest flag of each parameter is the most right digit.
These option flags are mapped on the flags 7664 - 7695. These flags have also been added to the
press.def file. Therefore with parameter 123 set to 0011 the flags 7664 and 7665 will be set to 1.
Variable Flag
M-OPTION1 7664
M-OPTION2 7665
... ...
M-OPTION32 7695
Note 1
If you are using the standard Delem sequencer and not creating your own sequencer, then these
parameters have no function.
Note 2
For more information about working with the sequencer file please refer to the sequencer
manual. This manual can be requested at Delem.