Delem
V0802, 3.2
The fields status, cyclus and communication information can have several values:
• The status number gives information about the Y-axes servo valve control.
1 = no valve control
2 = fast closing
3 = pressing (working stroke)
4 = holding at bending position
5 = decompression
6 = fast opening
7 = manual mode
8 = reference opening Y-axis
9 = reference closing Y-axis
• The cyclus number gives information about the backgauge status.
0 = No movement control of X-axis
-1 = Manual mode
-2 = Control waits until X-axis reference is passed
1 = Control waits until backgauge is in position, the beam is in UDP, and the
opening command is released
2 = Control waits until beam is at muting
3 = Control waits until beam is at clamping point
4 = Control waits until retract of backgauge is completed
5 = Control waits until beam is at bending position, and decompression is completed
6 = Control waits until beam is at muting point after bending (in opening direction
of beam)
7 = Control waits until upperbeam has moved from muting to UDP in opening
direction
8 = Control waits in UDP until dwell time in UDP has been expired.
11 = Wait until beam is in UDP in case of step-by-step mode when no auto-step-
change is selected.
12 = Waiting for C-input active in case step-change code CX = 4 or 5 is selected.
20 = Waiting until all axes have been started.
Note:
When an optional second servo axis is enabled, this will have consequences for cycle numbers -
2, and -1:
-2 = Control waits until X-axis and second servo-axis references are passed. (e.g. X2- or R-
axis)
-1 = Control waits until X-axis and second servo axis are both in position, the beam is in UPD
and the opening command is released.
When the second servo axis is configured as X2-axis also cycle number 4 is affected.
4 = Control waits until retraction of X-axis and X2-axis are both completed.