V1101, 3.25
Parameter 25: Output max.
Range : 0-255
Default : 255
Units : DA-points
Function
Pressure valve deflection for max. force.
Description
Output deflection for proportional pressure valve in DA-points to give max. force. There are two
ranges of pressure valves:
800 mA. These valves can be programmed to max. 136 DA-points.
1500 mA. These valves can be programmed to max. 255 DA-points.
See also calibration procedure with machine parameter Calibration.