Delem
V1101, 3.26
Parameter 26: Output min.
Range : 0-255
Default : 48
Units : DA-points
Function
Pressure valve deflection for minimal force.
Description
Output deflection for proportional pressure valve in DA-points to give min.force.
There are two ranges of pressure valves:
• 800 mA. These valves can be programmed to max 136 DA-points.
• 1500 mA. These valves can be programmed to max 255 DA-points.
See also calibration procedure with machine parameter Calibration.