EasyManua.ls Logo

Delem DA-69 - Page 91

Delem DA-69
239 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Delem
V1101, 3.55
Parameter 55: Punch clamp pressure
Range : 0-255
Default : 0
Units : DA-points
Function
Pressure setting for correct punch clamping.
Description
It is possible to control the pressure valve output for the hydraulic system, specifically meant for
the punch-clamp application. This can only be achieved by means of the sequencer file.

Related product manuals