Delem
V1101, 3.56
Parameter 56: Die clamp pressure
Range : 0-255
Default : 0
Units : DA-points
Function
Pressure setting for correct die clamping.
Description
It is possible to control the pressure valve output for the hydraulic system, specifically meant for
the die clamp application. This can only be achieved by means of the sequencer file.