Parameter 120: KO-table from floppy on/off 1/0
Range : 0 - 1
Default : 0
Units : -
Function
To read the KO-table from floppy.
Description
During development and testing of KO-tables it can be helpful to read this file from floppy
instead of loading a complete new application.
0 = using KO-table from the internal application;
1 = loading KO-table from floppy.
Press the key to select the required setting.
With this parameter set to 1 the KO-table is only read from floppy during start up.
After testing the KO-tables you should set this parameter to 0 again. Make sure the required KO-
table is on the application floppy with the other files and execute the normal application load
procedure.