Dell PowerEdge 6100/200 System Microprocessor Replacement 7
Table 1. Microprocessor Module Jumper Settings
Jumper
Setting Description
J6B1 (default) A processor is not installed in the
adjacent slot, the SKIP setting. This
jumper is useful only when you are
using in-target probe (ITP).
A processor is installed in the adja-
cent slot, the INCLUDE setting.
J6D1 (default) A processor is not installed in the
adjacent slot, the SKIP setting. This
jumper is useful only when you are
using ITP.
A processor is installed in the adja-
cent slot, the INCLUDE setting.
J4D1 (default) A 200/66 MHz microprocessor is
installed. See Table 2 for jumper set-
tings by microprocessor speed.
J4B1 (default) The fan heat sink jumper. Always set
to the default (passive).
J1C1 The processor(s) cache is 1 MB.
The processor(s) cache is 512 KB.
Table 2. Processor Frequency Select
Frequency SEL0 (Pins 1-2) SEL1 (Pins 3-4) SEL2 (Pins 5-6)
150/60 MHz No jumper No jumper No jumper
180/60 MHz Jumper No jumper No jumper
166/60 MHz No jumper No jumper Jumper
200/66 MHz Jumper No jumper Jumper
NOTE: A jumper is set on any of the three PARK settings (Pins 7-8, 9-10, or 11-12) for any
frequency selected.