Table 2. System Beep Codes
System Messages
The first column in Table 3 lists (in alphabetical order) system messages that may appear on the screen during the boot routine or during normal
system operation. The second column in the table lists probable causes of the messages, and the third column either provides a corrective action
or refers you to a source for resolving the problem.
Table 3. System Messages
Beep
Codes
Possible Cause
Corrective Action
1-2
No video card detected
Reseat the video card.
1-2-2-3
BIOS ROM checksum error
Refer to Chapter 7, "Getting Help," of the Reference and
Troubleshooting Guide for instructions on obtaining technical
assistance.
1-3-1-1
DRAM refresh error
Reseat the DIMMs.
1-3-1-3
8742 keyboard controller error
Reseat the keyboard connector.
1-3-3-1
Memory defective or not
present
Reseat the DIMMs.
1-3-4-1
RAM failure on line xxx
Reseat the DIMMs.
1-3-4-3
RAM failure on data bits xxx of
low byte on memory bus
Reseat the DIMMs.
1-4-1-1
RAM failure on data bits xxx of
high byte on memory bus
Reseat the DIMMs.
Message
Corrective Action
nnnn Cache RAM Passed
No action is necessary.
nnnn Extended RAM Passed
No action is necessary.
nnnn Shadow RAM Passed
No action is necessary.
nnnn System RAM Passed
No action is necessary.
CD ROM drive Identified
No action is necessary.
Diskette drive A error
Diskette drive B error
Ensure that the drive is installed correctly in the
chassis and defined correctly in the system
setup program.
Entering Setup
No action is necessary.
Extended RAM Failed at offset:
nnnn
If you receive this message after making
changes in the system setup program, enter the
program and restore the original value(s).
Failing bits: nnnn
If you receive this message after making
changes in the system setup program, enter the
program and restore the original value(s).
Fixed Disk n Failure
Fixed Disk Controller Failure
Ensure that the drive is installed correctly in the
chassis and defined correctly in the system
setup program.
Fixed Disk n Identified
No action is necessary.
Incorrect Drive x type - Run SETUP
Ensure that the drive is defined correctly in the
system setup program.
Invalid NVRAM media type
Set the configuration jumper to Maintenance
mode and restart the system to return all
settings to their defaults.