11 Dell PowerConnect 6224 or 6248 | Planning and Preparation Guide | Rapid EqualLogic Configuration Series
Table 4 PowerConnect 6224 and EqualLogic PS6100 point to point connections
Switch 1 Port
To
Switch 2 Port
To
1
Server 1, port 1
1
Server 1, port 2
2
Server 1, port 3*
2
Server 1, port 4*
Array 1
21
Controller 0, port 0
21
Controller 0, port 1
22
Controller 1, port 1
22
Controller 1, port 0
23
Controller 0, port 2
23
Controller 0, port 3
24
Controller 1, port 3
24
Controller 1, port 2
* Use of the 3rd and 4th host ports is optional. At least two ports are required.
Table 5 PowerConnect 6248 and EqualLogic PS6100 point to point connections
Switch 1 Port
To
Switch 2 Port
To
1
Server 1, port 1
1
Server 1, port 2
2
Server 1, port 3*
2
Server 1, port 4*
Array 1
21
Controller 0, port 0
21
Controller 0, port 1
22
Controller 1, port 1
22
Controller 1, port 0
23
Controller 0, port 2
23
Controller 0, port 3
24
Controller 1, port 3
24
Controller 1, port 2
* Use of the 3rd and 4th host ports is optional. At least two ports are required.

Other manuals for Dell PowerConnect 6248