support.dell.com Dell PowerEdge 2x50 and PowerApp 200 Systems Rack Installation Guide11
,QVWDOOLQJWKH6\VWHPVLQWKH5DFN
The subsections that follow include instructions for installing the PowerEdge 2x50 and
PowerApp 200 systems in the rack.
:$51,1*,I\RXDUHLQVWDOOLQJPRUHWKDQRQHV\VWHPLQVWDOOWKHILUVWV\V
WHPLQWKHORZHVWDYDLODEOHSRVLWLRQLQWKHUDFN
1HYHU
SXOOPRUHWKDQRQH
FRPSRQHQWRXWRIWKHUDFNDWDWLPH
1. Pull the two interior slide assemblies out of the rack until they lock in the
extended position.
&$87,21%HFDXVHRIWKHVL]HDQGZHLJKWRIWKHV\VWHPQHYHUDWWHPSWWR
LQVWDOOWKHV\VWHPLQWKHVOLGHDVVHPEOLHVE\\RXUVHOI
NOTE: Skip to step 3 if your system does not have the optional bezel installed.
2. Remove the optional bezel from the system front panel (see Figure 9):
a. Unlock and open the system doors.
b. Pivot the two locking levers toward the back of the chassis (see Figure 9).
c. Press the tab on each end of the bezel and remove the bezel from the
chassis.
d. Close the system doors.
)LJXUH5HPRYLQJWKH6\VWHP%H]HO
3. Lift the system into position.
Place one hand on the front-bottom of the system and the other hand on the
back-bottom of the system.
4. Tilt the system while aligning the back shoulder nuts on the sides of the system
with the back slots on the slide assemblies (see Figure 10).
tabs (2)
locking levers (2)