EasyManua.ls Logo

Dell PowerEdge 3250 - 4 SR870 BH2 SEL Data Tables; Table 1. SR870 BH2 Generator ID Codes; Table 2. SR870 BH2 Sensor Codes

Dell PowerEdge 3250
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SR870BH2 SEL Data Tables Intel® Server Platform SR870BH2
Revision 1.1
4
4. SR870BH2 SEL Data Tables
The tables in this section provide information on the data provided by the SEL Viewer utility.
Table 1. SR870BH2 Generator ID Codes
Generator ID Generator
20 00 BMC
CO 00 HSC
0x31 00 –0x3F 00 System BIOS or system software
Table 2. SR870BH2 Sensor Codes
Sensor Type Sensor Number Sensor Name
Temperature
20h Memory Board Temp
21h Memory Board SNC Temp
22h PCI Riser SIOH Temp
23h Peripheral Board AMB Temp
24h PCI Riser board Temp
25h CPU Area Temp
26h Memory Area Temp
81h Processor 1 Temp
01
82h Processor 2 Temp
Voltage
10h MB Bd +1.25V
11h MB Bd +1.5V
12h MB Bd +1.8V
13h MB Bd +3.3V
14h MB Bd +3.3V SB
15h MB Bd +5V
16h MB Bd +12V
17h MB Bd –12V
18h MB Bd +1.2V
19h MB Bd +1.3V
1Ah MB Bd –1.5V SB
1Bh MB Bd +2.5V
1Ch MB Bd +2.5V SB
1Dh MB Bd 2 +5V SB
50h LVDS SCSI channel 1 terminator 1
51h LVDS SCSI channel 1 terminator 2
52h LVDS SCSI channel 1 terminator 3
53h LVDS SCSI channel 2 terminator 1
02
54h LVDS SCSI channel 2 terminator 2

Other manuals for Dell PowerEdge 3250

Related product manuals