14 Rack Installation Guide
Figure 1-6. Installing the VersaRails Mounting Rails
Installing and Removing Chassis Static Rail Modules
NOTE: You do not need to remove the optional front bezel to install or remove the chassis static rail
modules from the chassis.
1
To install the rails, locate the J slots on both rails. Locate the two corresponding shoulder
screws that are on both sides of the chassis toward the front and midpoint (see Figure 1-7).
2
To attach the rails to the chassis, align the two J slots on the rail modules with the shoulder
screws. Position each rail directly below the two corresponding shoulder screws
(see Figure 1-7).
3
To seat the rails, pull up on the front latches attached to the front of each rail. Pull up
and back on each rail, snapping them into place on the chassis.
4
To remove the rails from the chassis, pull up on the front latches to release each rail.
5
Unseat the rails from the J slots and remove the rails from the chassis.