EasyManua.ls Logo

Dell PowerEdge FX2 - 3 Poweredge Fx2;Fx2 S Mapping Configurations; LAN on Motherboard Network; Supported I;O Modules

Dell PowerEdge FX2
91 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NOTE: In the six-bay PowerEdge FX2s configuration that supports storage sleds mapped to quarter-width compute sleds,
the I/O module ports are mapped only to the compute sleds. If storage sleds are installed, the corresponding ports on the
I/O modules mapped to these slots are not active.
Figure 19. I/O module port mapping—six-bay chassis
The following table lists the compute sleds and the ports to which they are mapped.
Table 10. I/O module port mapping in a six-bay chassis
Compute
sled
IO Module A1 (Top) IO Module A2 (Bottom)
1a 1 1
1b 2 2
1c 3 3
1d 4 4
3 5, 6 (for half-width compute sled with quad-port
NDC)
5, 6 (for half-width compute sled with quad-port
NDC)
5 (for half-width compute sled with dual-port NDC) 5 (for half-width compute sled with dual-port NDC)
4 7, 8 (for half-width compute sled with quad-port NDC) 7, 8 (for half-width compute sled with quad-port NDC)
7 (for half-width compute sled with dual-port NDC) 7 (for half-width compute sled with dual-port NDC)
I/O module port mapping—two-bay chassis
In the two-bay chassis configuration that supports up to two full-width compute sleds, a compute sled is mapped to four ports
on each I/O module.
Figure 20. I/O module port mapping—full-width compute sleds
PowerEdge FX2/FX2s mapping configurations