56 Dell EMC Networking with Isilon Front-End Deployment and Best Practices Guide | version 1.0
The upstream interfaces and port channels will be configured as follows:
S4048-ON Leaf 3
S4048-ON Leaf 4
interface port-channel50
description Spine 1 and 2
no shutdown
switchport
mtu 9216
vlt-peer-lag port-channel 50
interface fo 1/49
description Spine 1
no shutdown
port-channel-protocol LACP
port-channel 50 mode active
mtu 9216
interface fo 1/50
description Spine 2
no shutdown
port-channel-protocol LACP
port-channel 50 mode active
mtu 9216
interface port-channel50
description Spine 1 and 2
no shutdown
switchport
mtu 9216
vlt-peer-lag port-channel 50
interface fo 1/49
description Spine 1
no shutdown
port-channel-protocol LACP
port-channel 50 mode active
mtu 9216
interface fo 1/50
description Spine 2
no shutdown
port-channel-protocol LACP
port-channel 50 mode active
mtu 9216
Next, we will create the VLANs. There will be one VLAN for each Isilon subnet; this will also include the
servers in each rack.
S4048-ON Leaf 3
S4048-ON Leaf 4
interface vlan200
no shutdown
untagged port-channel 1,3,5,101,102
tagged port-channel 50
interface vlan200
no shutdown
untagged port-channel 1,3,5,101,102
tagged port-channel 50
Uplink Failure Detection (UFD) is configured next. UFD shuts down all downstream interfaces if all uplinks