EasyManua.ls Logo

Dell PowerVault MD3620f - Page 27

Dell PowerVault MD3620f
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cabling Your Cluster Hardware 27
Figure 2-4. Cabling a Two-Node Direct-Attached Cluster to a PowerVault MD36
x
0f
Storage System
NOTE: The SAS out port provides SAS connection for cabling to MD1200 or
MD1220 expansion enclosure(s).
Cabling a Four-Node Direct-Attached Cluster to an MD36x0f Storage System
You can configure a cluster with more than two nodes in a direct-attached
configuration using a PowerVault MD36x0f storage system. The MD36x0f
storage system can support up to four-node direct-attached cluster.
The following example explains how to cable a four-node direct-attached
cluster:
1
Connect cluster node 1 to the storage system:
a
Install a cable from cluster node 1 HBA port 0 to the Fibre Channel
port on the MD36
x
0f RAID controller module 0, port In-0.
Corporate, public, or
private network
cluster node1
cluster node2
SAS out port (2)
RAID controller module 0
RAID controller module 1
book.book Page 27 Monday, July 25, 2011 3:18 PM