28 Cabling Your Cluster Hardware
b
Install a cable from cluster node 1 HBA port 1 to the Fibre Channel
port on the MD36
x
0f RAID controller module 1, port In-0.
2
Connect cluster node 2 to the storage system:
a
Install a cable from cluster node 2 HBA port 0 to the Fibre Channel
port on the MD36
x
0f RAID controller module 0, port In-1.
b
Install a cable from cluster node 2 HBA port 1 to the Fibre Channel
port on the MD36
x
0f RAID controller module 1, port In-1.
3
Connect cluster node 3 to the storage system:
a
Install a cable from cluster node 3 HBA port 0 to the Fibre Channel
port on the MD36
x
0f RAID controller module 0, port In-2.
b
Install a cable from cluster node 3 HBA port 1 to the Fibre Channel
port on the MD36
x
0f RAID controller module 1, port In-2.
4
Connect cluster node 4 to the storage system:
a
Install a cable from cluster node 4 HBA port 0 to the Fibre Channel
port on the MD36
x
0f RAID controller module 0, port In-3.
b
Install a cable from cluster node 4 HBA port 1 to the Fibre Channel
port on the MD36
x
0f RAID controller module 1, port In-3.
book.book Page 28 Monday, July 25, 2011 3:18 PM