Serial connector (debug port) One mini-USB port
NOTE: For technical support use only.
Management Ethernet connector One 100/1000 Mbps Ethernet connection for out-of-
band management of the enclosure (MGMT)
Table 11. Power
AC power supply (per power supply)
Wattage 600 W
Heat dissipation (maximum)
NOTE: Heat dissipation is calculated 
using the power supply wattage 
rating. The heat dissipation values are 
for the entire system which includes 
chassis and two controllers.
100 W
Voltage
NOTE: This system is also designed to 
be connected to IT power systems 
with a phase to phase voltage not 
exceeding 230 V.
100–220 V AC, (8.6 A-4.3 A)
Battery 6.6 V DC, 1100 mAh, 7.26 W Lithium ion battery
Table 12. Environmental
NOTE: For additional information about environmental measurements for specific system 
configurations, see dell.com/environmental_datasheets.
Temperature
Operating Continuous operation: 10 °C to 35 °C (50 °F to 95 °F) at 
20% to 80% relative humidity (RH), with 26 °C 
maximum dew point. De-rate maximum allowable dry 
bulb temperature at 1 °C/300 m (1 °F per 550 ft) above 
900 m (2952.75 ft).
NOTE: For information on supported expanded 
operating temperature range and configurations, 
see the Owner's Manual at dell.com/
powervaultmanuals.
Storage –40 °C to 65 °C (–40 °F to 149 °F) with a maximum 
temperature gradation of 20 °C per hour
Relative humidity
Operating 10% to 80% (noncondensing) with maximum humidity 
gradation of 10% per hour