19. Adjust the GREEN on OSD, until chroma 7120 indicator reached G=100
20. Adjust the BLUE on OSD, until chroma 7120 indicator reached B=100
21. Repeat above procedure (item 5,6,7) until chroma 7120 RGB value meet the tolerance =100±2
22. Move cursor to “ Exit/Save” sub-menu and press MENU key to save adjust value and exit.
Turn the POWER-button off to on to quit from factory mode.
Max. BRIGHTNESS:>250 cd/m2
Test conditions: -Center of display (1)
- Video input (RGB) = 0.700V
- Brightness control is set to max
- Contrast control is set to max.
MIN. BRIGHTNESS
< 40% of max Luminance (max Luminance = set the brightness and contrast to max value)
Test conditions: - Center of display (1)
- Video input (RGB) = 0.700V
- Brightness control is set to min.
- Contrast control is set to min.