9. ALARMS SHOWN ON DISPLAY
ALARM CAUSE SOLUTION
Tank (A2) missing or incorrectly
positioned
Place the tank back in its correct position (see para-
graph “4.1 Draining into the tank”)
Tank full Empty the tank (see paragraph “4.1 Draining into the
tank”)
Room temperature too low (see op-
erating limits in chap. “8. Technical
Specications”)
Increase the ambient temperature if possible
Faulty probe Contact the Service Centre
10. TROUBLESHOOTING
Below is a list of possible malfunctions.
If the problem cannot be solved using the proposed solution, contact the Service Centre.
PROBLEM CAUSE SOLUTION
The appliance is operating in dehumid-
ifying mode, but the humidity does not
decrease
The lter is clogged Clean the dust lter (para. “7.2 Cleaning
the dust lter”)
Either the temperature or humidity in the
room is too low
In certain conditions the appliance will
not dehumidify: check the operating lim-
its of the appliance (see chapter “8. Tech-
nical Specications”). In certain cases, it
is recommended to heat the room need-
ing to be dehumidied.
The set relative humidity level is too high Set a lower humidity value (see para. “5.1
Dehumidifying mode”).