GENERAL SAFETY INSTRUCTIONS
Cylinder valve
If heater does not completely extinguish, including pilot, when gas is turned off, do not remo-
ve regulator. Return valve to open position and leave heater alight, which is perfectly safe,
until attended to by the gas supplier.
Regulators, hoses and clips
Check that tubing is completely over the nozzles at each end of the
tubing and that it is held firmly in place by hose clips. Examine flexible
tubing regularly and get your dealer to fit new tubing 400 mm long
complying to local standard, if perished, worn or damaged. In any
case replace the tube every 5 years. L.P.G. attacks natural rubber - use
only tubing to B.S. 3212 Type 2 supplied by your dealer.
When connecting the regulator to the container avoid undue twisting of the flexible hose.
A regulator to B.S. 3016 set at 28 mbar (11,2 in w.g.) for butane must be connected to the
appliance with the above tubing, using suitable hose clips.
Ventilation
Use only in a well ventilated room.
Adequate ventilation must be provided in rooms in which
the heater is used. This ensures removal of the products of
combustion and allows the entry of replacement air.
Adequate ventilation should considerably reduce the
possibility of condensation occurring.
The following table shows the smallest size of room suita-
ble for the heater and the ventilation which must be provided. The heater may be used for
short periods in smaller rooms.
Maintenance
Ensure that the heater is kept free of dust. When not in use the heater should be covered and
stored in a dust-free place. Stains on the exterior should be removed with a soapy solution
when the heater is cold. Dry with a polishing cloth do not use abrasive cleaners which will
damage the paint finishes. Refer any major maintenance to your Local Authorised Dealer
Major servicing should be carried out every 2 - 3 years. If in doubt refer to your authorised
dealer.
Safety guard:
The guard on this appliance conforms to the requirements of B.S. 1945: 1971 and satisfies the
heater appliances (fireguards) regulations. The guard is to prevent risk of fire or injury from
burns and no part of it should be permanently removed.
It does not give full protection for young children or the infirm.
Positioning the heater:
DO NOT PLACE clothes or other materials on the heater.
DO NOT POSITION heater close to chairs or fabrics.
DO NOT MOVE the heater across the room when lit.
DO NOT POSITION the heater alongside a wall or near curtains etc.
ALWAYS face the heater towards the centre of the room.
Type Category Max. Input Low Input Gas pressure
Gas combustion
air-quantity
See rating label
This appliance is designed to operate with Butane, propane or mix. LPG at nominal pressure: 28÷30 mbar
Kw g/h
4,2 305
Kw g/h
1,50 109
28÷30 mbar 8,4 m
3
/h
Room Size Room Aperture
42 m
3
105 cm
2