Electrical System and Instruments
REMOVING -
Rgs.
13, 14 and 15
1.
Disconnect Battery.
2.
Remove Diagnostic Socket (1) by pressing on
Lugs (2) and pull down Socket out of Bracket
(3).
Fig. 14
3. Disconnect Earth Wire, Lambda Control Wire
and Feed Wire.
4.
Remove Screw (4), holding Pick-Up (5) and
remove. Fig. 15
2.
Re-clip Diagnostic Socket into Bracket.
NEW PICK-UP - Fig. 16
The pick-up (5) has three Lugs which set its
position.
Bring the three Lugs into contact with the
Flywheel (6) and tighten Screw (4).
REUSING AN OLD PICK-UP
If the Lugs are worn, push the pick-up (5) in until it
touches the Flywheel (6). Mark its position and
withdraw it
1
mm A (.040" A). Tighten Screw i4).
RE-FIT
ADJUSTING PICK-UP
The pick-up (5) should be set 0, to
1
mm A
(.020'
to .040" A) from Flywheel (6).
REFITTING
1.
Reconnect Earth Wire, Lambda Control Wire
and Feed Wire.
^