50 51
EN
D
Remove an associaon (the removal method varies according to the
transmier associated, refer to the transmier's user guide)
Example of removing a remote control associaon.
On the receiver:
- Press the receiver buon for 10 seconds unl the LED ashes rapidly, release.
On the remote control:
- Press the
and buons for 3 seconds.
- Make sure that the receiver LED has stopped ashing. The products are no longer
associated.
E
Remove all associaons
- Press the receiver's buon for 20 seconds.
- Press and hold unl the LED switches o aer the rapid ashing phase.
- Release. The receiver has no wireless connecon.
F
Factory reset
- Press the receiver buon for 30 seconds, the LED ashes then switches o,
The receiver has no wireless connecon and the conguraon is reset (mode 1 by
default).
5/ TROUBLESHOOTING 6/ TECHNICAL CHARACTERISTICS
6.1 TYXIA 2330 TRANSMITTER SWITCH
• Baery life of 10 years CR 2430
• Radio frequency 868,7 MHz to 869,2 MHz
• Maximum wireless power < 10 mW
• Category 2 receiver
• Wireless range: 100 to 300 metres outside, variable depending on the associated
equipment (the range can vary depending on the installaon condions and the
electromagnec environment)
• Class III insulaon
• Dimensions: 80 x 80 x 11 mm
• Degree of protecon: IP 40, IK 04
• Operang temperature: -10 °C/+40 °C
• Storage temperature: -10 °C/+70 °C
• Installaon in an environment with normal polluon levels