EasyManua.ls Logo

DELTA DORE TYDOM 1.0 - Page 14

DELTA DORE TYDOM 1.0
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
52 53
EN
6.2 TYDOM 1.0 HOME AUTOMATION BOX
• Main power supply 230 V~/240 V~, +/-10%, 50/60 Hz,
• Radio frequency 868.7 MHz to 869.2 MHz
• Maximum wireless power < 10 mW
• Category 2 receiver
• Wireless range: 100 to 300 metres outside, variable depending on the associated
equipment (the range can vary depending on the installaon condions and the
electromagnec environment)
• Class III insulaon
• Dimensions: 100 x 100 x 30 mm
• Degree of protecon: IP 30
• Operang temperature: -10 to +40°C
• Storage temperature: -20 to +70°C
• Installaon in an environment with normal polluon levels
The connecon quality of your product may be aected due to changes on the
IP architecture on which it operates. These changes may involve (the list is not
exhausve) a change in hardware, a soware update or conguraon operaons,
and work on your operator's equipment or any other mulmedia devices such as
tablets, smartphones, etc.' Android™ and Google play are Google Inc trademarks.
IOS™ is a Cisco Systems Inc trademark. WiFi is a Wireless Ethernet Compability
Alliance trademark. Because of changes in standards and equipment, the
characteriscs given in the text and the illustraons in this document are not
binding unless conrmed.
6/ TECHNICAL CHARACTERISTICS
6.3 TYXIA 6610 TRANSMITTER SWITCH
• Main power supply 230 V~/240 V~, +/-10%, 50/60 Hz, 2 VA
• Radio frequency 868.7 MHz to 869.2 MHz
• Maximum wireless power < 10 mW
• Category 2 receiver
• Wireless range: 100 to 300 metres outside, variable depending on the associated
equipment (the range can vary depending on the installaon condions and the
electromagnec environment)
• Dimensions: 77 x 37 x 27 mm
• Degree of protecon: IP 40, IK 04
• Operang temperature: 0 °C/+40 °C
• Storage temperature: -10 °C/+70 °C
• Polluon level: 2
• Rated impulse withstand voltage: 2.5 kV
• Operaon type: S1 connuous duty service S1
• Switch type: 1 single pole
• Number of operang cycles: 100,000
• Circuit cut-o: Brownout µ
• Number of receivers: 16 maximum

Other manuals for DELTA DORE TYDOM 1.0

Related product manuals