EasyManua.ls Logo

Delta 591T Series - User Manual

Delta 591T Series
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Page 1
212294 Rev. B
591T__ 2 __ __
Write purchase model number here for future reference
PLEASE LEAVE this M&I Sheet with the owner, maintenance plumber, etc. as
items relating to ongoing maintenance suggestions and procedures are included.
NOTE: Control Box #0 and #1 are designed for routine
171°F (77°C) disinfection cycles up to 30 minutes.
Control Box #8 is not recommended for high temperature
disinfection cycles as the thermostatic mixing valve limits
the higher temperature flow output.
NOTE: For optimum performance of this product, we
recommend a system pressure between 20 and 80 PSI
static. This product will operate up to a maximum of 125
PSI static per ANSI and CSA requirements. However,
we do not recommend pressure above 80 PSI. Thermal
expansion or leaking pressure reducing valves may
require use of expansion tanks or relief valves to ensure
your system never exceeds its maximum intended
pressure setting.
060638A
Vandal Resistant Laminar Outlet
with Antimicrobial by Agion
®
1.5 GPM (5.7 L/min)
060640A
Vandal Resistant Flow Control
Aerator and Wrench
1.5 GPM (5.7 L/min)
061203A
Vandal Resistant Laminar
Outlet with Wrench
0.5 GPM (1.9 L/min)
061176A
Vandal Resistant Laminar
Outlet with Wrench
1.0 GPM (3.8 L/min)
061104A
Vandal Resistant Flow Control
Non-Aerating Spray Outlet
with Wrench
0.35 USGPM (1.3 L/min)
RP31704 - Optional
Vandal Resistant Spray
Outlet with Wrench
0.5 GPM (1.9 L/min)
060566A - Optional
Vandal Resistant Spray
Outlet with Wrench
1.0 GPM (3.8 L/min)
RP6001
Nut & Washer
060765A
Wrench
063211A
Spout Assembly
Fig. 1
062032A
Braided Polymer Hose
OPTION LIST
TRANSFORMERS
060704A
Transformer 110 to 24 VAC 20VA
up to 5 Electronic Valves
060771A
Transformer 110 to 24 VAC 40VA
up to 10 Electronic Valves
212294 212294 212294 212294 212294
212294 212294 212294 212294 212294
061031A
Deck Gasket (3/pkg)
Note: See page 3 for
parts breakdown on
recessed mount boxes.
www .specselect.com
060683A
24 VAC/6.4 VDC
Converter
061256A
36” Cable Extension
Accessories
060681A
Battery Holder
063257A
3/4” Solenoid Valve
w/adaptors for 3/8”
Compression
063258A
Surface Box Assembly (less driver board)
w/ 3/4” solenoid and adaptors for 3/8” compression
060908A
Solenoid Holder
063257A
3/4” Solenoid Valve
w/adaptors for 3/8”
Compression
061252A
Dual Driver
Board Masco
H
2
Optics
& Proximity
060906A
Surface
Mount Housing
060905A
Cover Gasket
Question and Answer IconNeed help?

Do you have a question about the Delta 591T Series and is the answer not in the manual?

Delta 591T Series Specifications

General IconGeneral
BrandDelta
CategoryKitchen & Bath Fixtures
Product TypeFaucet
ADA CompliantYes
Handle TypeLever
Series591T
Number of Holes Required1
Flow Rate1.5 gpm
FinishChrome
Installation TypeWall Mount
WarrantyLimited Lifetime

Summary

Installation and Set Up Instructions for Surface Mount Housing: Control Box #0

Faucet Installation

Instructions for mounting the faucet to the sink surface using provided hardware and gasket.

Battery Box Installation

Guidance on mounting the battery box under the sink within specific dimensions.

Flush System

Procedure to flush the supply line with water before connecting the solenoid.

Connect Water Supply

Steps for connecting the water supply line and adaptor to the control box.

Power Up

Instructions for powering the unit using batteries or a 24 VAC converter.

Prepare Sink Area

Cleaning the sink area and removing objects before connecting the spout cable.

Tie Spout Cable

Securing the spout cable to the spout hose using tie wraps.

Test for Operation

Performing initial tests and troubleshooting common issues like leaks or low flow.

Installation and Set Up Instructions for Recess Mount Housing: Control Boxes #1 & 8

Rough In

Guidelines for protecting wires, installing the transformer, and roughing in water supply and drainage.

Faucet Installation

Mounting the faucet to the sink surface, ensuring proper gasket placement.

Connect Water Supply

Connecting water supply lines to the control box inlets and spout.

Flush System;Set Temperature

Flushing lines, setting desired water temperature using the mixing valve.

Connect Electrical Supply, Solenoid Valve and Sensor

Connecting power, solenoid, and sensor wires for battery or hardwire installations.

Services

Final steps including opening stops, flushing lines, and installing the aerator.

Test for Operation

Verifying proper function and referring to troubleshooting guides if issues arise.

Making Adjustments

Overview of adjusting sensor range, timers, and other faucet settings.

Troubleshooting Guide

Error Code Identification

Procedure to identify issues by checking error codes displayed via TOGGLE button.

Operation Checks

Troubleshooting steps for no operation, shutdowns, beeping noises, and intermittent flow.

Solenoid and Electrical Issues

Diagnosing problems related to solenoid clicks, pressure locks, and electrical interference.

Delta Commercial Faucet Limited Warranty

Related product manuals