Chapter 8 Load Cell Module AS02LC
8- 7
CR# Name Description
Att.
Default
3:6 mV/V
4:20 mV/V
5:40 mV/V
6:80 mV/V
61 Sampling cycle for CH2
0:2.5 ms
1:10 ms
2:16 ms
3:20 ms
4:50 ms
5:60 ms
6:100 ms
7:200 ms
8:400 ms
R/W
4
62
Weight measured times in a
stability range for CH2
Range: K1–K500
R/W
5
63
Stability range for CH2
Floating-point format
Range: 0–100000
R/W
10
64
65
Maximum weight for CH2
Floating-point format
Maximum measuring weight; when the
weight measured exceeds the limit, an
alarm is triggered. The value should be
greater than 1.
R/W
100,000
66
67 Filter mode for CH2
0: no filter (default)
1: maximum filter mode
2: average filter mode
R/W
0
68 Maximum filter for CH2
Range: 0–8; the bigger the number the
stronger the filter
R/W
1
69
Average weight measured
times for CH2
Range: 1–100
(for FW V1.04: 1–400 is available)
R/W
10
70
Upper limit of the zero return
for CH2
Floating-point format
Determines the current weight as the zero
point in the upper/lower range; when the
lower range is larger than the upper range,
R/W
10
71
72
Lower limit of the zero return
for CH2
R/W
-10
73