Page #262 background image
AS Series Module Manual
8- 8
_8
CR# Name Description
Att.
Default
the lower range is read as the upper range
and vice versa.
74
Zero point tracking time for
CH2
Range: 5–500
Unit: 100 ms
R/W
10
75
Zero point tracking range for
CH2
Floating-point format
Range: 0–10000; 0: disabled
R/W
0
76
77 Calibration points for CH2 Range: 2–20
R/W
2
78–117 Calibrated weight for CH2
Floating-point format
Calibrated weight of the calibration points
1–20
R/W
-
118 Decimal place for CH1 Range: 0–4
R/W
1
119 Decimal place for CH2 Range: 0–4
R/W
1
120 Alarm
0: warning
1: alarm
Bit0: error in the power supply
Bit1: error in the module hardware
Bit2: error in the driver board
R/W
1
200 State register Refer to the explanation below.
R/W
-
201 Command set Refer to the explanation below.
W
0
210
The maximum peak value for
CH1
Floating-point format
Maximum peak value for CH1
R
-
211 -
212
The maximum peak value for
CH2
Floating-point format
Maximum peak value for CH2
R
-
213 -
214
The minimum peak value for
CH1
Floating-point format
Minimum peak value for CH1
R
-
215 -
216
The minimum peak value for
CH2
Floating-point format
Minimum peak value for CH2
R
-
217 -
222 The time to record for CH1 Unit: 1 ms
Range: 1–100 (1 ms–1 s)
Time to record the digital value for the
channels
R/W
50
223 The time to record for CH2 50
240 The number of records for CH1
Range: 0–500; display the current records
R
-