#2
TB1 X0.0 X0.2 X0.4 X0.6 X0.8 X0.10 X0.12 X0.14 S/S -
TB2 X0.1 X0.3 X0.5 X0.7 X0.9 X0.11 X0.13 X0.15 S/S -
Wiring the External Terminal Module UB-10-ID32A
Input form
Direct current (sinking or sourcing)
Input current/voltage
24 VDC, 5 mA
Length
39 40
39 40
1 2
1 2
UC-ET010-24B(1M)
UC-ET020-24B(2M)
UC-ET030-24B(3M)
Length:
X0.0
X0.1
X0.14
X0.15
X0.2
X0.3
X0.4
X0.5
X0.6
X0.7
X0.8
X0.9
X0.10
X0.11
X0.12
X0.13
X1.0
X1.1
X1.14
X1.15
X1.2
X1.3
X1.4
X1.5
X1.6
X1.7
X1.8
X1.9
X1.10
X1.11
X1.12
X1.13
S/S
S/S
S/S
S/S
Upper row
Lower row
24 V DC, 5 mA
Note: UB-10-ID32A can be used with AS Series and DVP Series. The indications on the UB-10-ID32A board is
for DVP Series. For the definitions of terminal connections for AS Series, you can see the reference table below.
Or refer to the enclosed sticker for AS Series.
Upper
row
AS X0.0 X0.2 X0.4 X0.6 X0.8
X1.0 X1.2 X1.4 X1.6 X1.8
S/S S/S
DVP X0 X2 X4 X6 X10 X12 X14 X16 X20 X22 X24 X26 X30 X32 X34 X36 S/S S/S
Lower
row
DVP X1 X3 X5 X7 X11 X13 X15 X17 X21 X23 X25 X27 X31 X33 X35 X37 S/S S/S
AS X0.1 X0.3 X0.5 X0.7 X0.9 X0.11 X0.13 X0.15 X1.1 X1.3 X1.5 X1.7 X1.9 X1.11 X1.13 X1.15 S/S S/S