Chapter 2 Settings and Measurements
LD-E Operation Manual
2-3
Single point teaching (window comparison mode)
Single point teaching is used for the distance between the reference plane of the detection object, the
method of setting the upper and lower limits, and the output between the upper and lower limits.
After the reference plane of the detection object is taught
1_SL = The height of the detection object minus 2 times the hysteresis
2_SL = The height of the detection object plus 2 times the hysteresis
1. With the detection object, press twice. (1
st
time: TEACH mode, 2
nd
time: teaching)
2. After teaching, press once to leave.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta LD-100E-M22 and is the answer not in the manual?