4
VFD-V Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
4-1
CHAPTER 4 DIGITAL KEYPAD (VFD-PU05) OPERATION
4.1 Description of the Digital Keypad VFD-PU05
U
F
H
VFD-PU05
JOG
RUN
RESET
STOP
MODE Selection key
Press this key to view different
operating values
LED Display
Display frequency, current, voltage
and error, etc.
Status Display
Display the driver's current status
When "PU" lights, RUN/STOP is
controlled by PU05. When "PU" is
dark, RUN/STOP is set by 00-21.
When "EXT" lights, frequency
command and torque command
is set by 00-20. When "EXT" is dark,
it is controlled by PU05.
Part Number
STOP/RESET
Left key
moves cursor to the left
PU
EXT PU
Right key
Moves the cursor right
FWD/REV Direction key
RUN key
4.2 Explanations of Display Messages
Messages Displayed Descriptions
Master frequency of the drive
A
ctual operation frequency output to the motor from
the drive
User-selected content (the side DC-BUS voltage)
Question and Answer IconNeed help?

Do you have a question about the Delta VFD-PU05 and is the answer not in the manual?

Summary

Digital Keypad (VFD-PU05) Operation

Digital Keypad VFD-PU05 Description

Details on the VFD-PU05 digital keypad components, including status indicators, operation keys, and display elements.

Display Messages Explained

Explanations for various messages displayed on the keypad, such as frequency and output values.

Keypad Display Messages and Functions

Output Current Display

Explains the display of output current and its significance.

Parameter Duplication Function

Describes the process for duplicating parameters using PROG/DATA and UP/DOWN keys.

Parameter Item and Value Display

Details on displaying specific parameter items and their corresponding content values.

End and Error Message Indicators

Explanation of 'End' for saved data and 'Err' for invalid data or out-of-limit values.

Digital Keypad Operation Flow

Frequency Command and Adjustment

Guide to changing frequency commands using UP/DOWN and adjusting numbers with RIGHT/LEFT keys.

Parameter Save and Copy Operation

Steps for saving and copying parameters between the drive and keypad using PROG/DATA.

Parameter Write Status

Indicates successful writing of parameters ('-END-') or failure ('-ERR-').

Delta VFD-PU05 Specifications

General IconGeneral
ModelVFD-PU05
TypeKeypad
CommunicationRS-485
Protection LevelIP20
SeriesVFD
Compatible VFD SeriesVFD-E, VFD-EL, VFD-M, VFD-VE, VFD-C2000