Chapter  13  Warning  CodesCP2000 
 
13-35
ID No.  Display on LCD Keypad  Warning Name  Description 
80 
 
Ethernet link fail 
(ECEF) 
Ethernet cable is not connected 
Action and Reset 
Action level  Hardware detection 
Action time  Immediately acts 
Warning setting parameter  N/A 
Reset method  Manual reset 
Reset condition  N/A 
Record  N/A 
Cause  Corrective Actions 
Ethernet cable is loose  Re-connect the cable 
Bad quality of Ethernet cable  Replace the cable 
 
ID No.  Display on LCD Keypad  Warning Name  Description 
81 
 
Communication 
time-out   
(ECto) 
Communication  time-out  for  communication  card  and 
the upper unit 
Action and Reset 
Action level  N/A 
Action time  N/A 
Warning setting parameter  N/A 
Reset method  N/A 
Reset condition 
CMC-EC01: auto resets when the communication with the upper unit is back to 
normal 
Record  N/A 
Cause  Corrective Actions 
Communication card is not 
connected with the upper unit 
Check if the connection of the communication cable is correct 
Communication error of the upper 
unit 
Check if the communication of the upper unit is normal 
 
ID No.  Display on LCD Keypad  Warning Name  Description 
82 
 
Checksum error 
(ECCS) 
Checksum error for communication card and the drive 
Action and Reset 
Action level  Software detection 
Action time  N/A 
Warning setting parameter  N/A 
Reset method  Manual reset 
Reset condition  Immediately resets 
Record  N/A 
Cause  Corrective Actions 
Noise interference 
Verify  wiring  of  the  control  circuit,  and  wiring/grounding  of  the  main  circuit  to 
prevent interference.