EasyManua.ls Logo

Delta VFD110ED43S - Page 220

Delta VFD110ED43S
447 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 11 Summary of Parameter Settings | VFD-ED
11-11
Pr. Parameter Name Setting Range Default
VF
VFPG
SVC
FOCPG
FOCPM
45: Reserved
46: Retrying after a fault has occurred
indication
○ ○
○
○
○
47: Direct docking mode only
◆
48: Control output of MPSCC (Motor
Phase Short Circuit Contactor)
○ ○
○
○
○
49: Emergency power mode action
○
○
○
○
○
50: Speed reached Pr.02-34
○
○
○
○
○
51: Brake torque test finished
○
○
○
○
○
52: AFE reset
○
○
○
○
○
02-21–02-22
Reserved
02-23
Multi-output Direction
0–65535
0
○
○
○
○
○
02-24
Serial Start Signal
Selection
0: According to FWD/REV signal
1: According to Enable drive function
signal
0 ○ ○
○
○
○
02-25
Desired Frequency
Reached 1
0.00–299.00 Hz
60.00/
50.00
○ ○
○
○
○
02-26
Desired Frequency
Reached Width 1
0.00–299.00 Hz 2.00 ○ ○
○
○
○
02-27
Desired Frequency
Reached 2
0.00–299.00 Hz
60.00/
50.00
○ ○
○
○
○
02-28
Desired Frequency
Reached Width 2
0.00–299.00 Hz 2.00 ○ ○
○
○
○
02-29
Brake Release Delay
Time when Elevator
Starts
0.000–65.000 sec. 0.250 ○ ○
○
○
○
02-30
Brake Engage Delay
Time when Elevator
Stops
0.000–65.000 sec. 0.250 ○ ○
○
○
○
02-31
Magnetic Contactor
Contracting Delay Time
between Drive and
Motor
0.010–65.000 sec. 0.200 ○ ○
○
○
○
02-32
Magnetic Contactor
Release Delay Time
between Drive and
Motor
0.010–65.000 sec. 0.200 ○ ○
○
○
○
02-33
External Terminal
Output Current Level
0–100% (motor drive rated current) 0 ○ ○
○
○
○
02-34
External Terminal
Output Speed Limit
0.00–299.00 Hz (this is motor speed
when using with PG)
NOTE: The setting range and unit of
Pr.02-34 varies with Pr.00-10 settings.
See Chapter 12 for details.
0.00 ○ ○
○
○
○
02-35
Mechanical Brake
Detection Time
0.00–10.00 sec. 0.00 ○ ○
○
○
○

Table of Contents