EasyManua.ls Logo

Delta VFD110ED43S

Delta VFD110ED43S
447 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12 Descriptions of Parameter Settings | VFD-ED
12-02-2
Multi-function Input Command 5 (MI5)
Default: 0
Multi-function Input Command 6 (MI6)
Default: 0
Multi-function Input Command 7 (MI7)
Default: 0
Multi-function Input Command 8 (MI8) (Enable Drive terminal)
Default:40
Settings Control Mode
VF VFPG SVC FOCPG
FOCPM
0: No function
1: Multi-step speed command 1
2: Multi-step speed command 2
3: Multi-step speed command 3
4: Multi-step speed command 4
5: Reset
6: JOG command
7: Acceleration/deceleration speed inhibit
8: First, second
acceleration/deceleration time
9: Third, fourth
acceleration/deceleration time
10: EF input (Pr.07-28)
11: Reserved
12: Stop output
1314: Reserved
15: AUI1 operation speed command
16: Reserved
17: AUI2 operation speed command
18: Emergency Stop (Pr.07-28)
1923: Reserved
24: FWD JOG Command
25: REV JOG Command
26: Reserved
27: ASR1/ASR2 selection
28: Emergency stop (EF1) (motor coasts to stop)
2930: Reserved
31: High torque bias (according to Pr.07-21)
32: Middle torque bias (according to Pr.07-22)
33: Low torque bias (according to Pr.07-23)
3437: Reserved
38: Disable writing to EEPROM
39: Torque command direction (0 is positive
direction)
40: Enable drive function

Table of Contents