Chapter 11 Summary of Parameter SettingsMS300
255
13 Industry Application Parameters
Pr.
Explanation
Settings
Default
13-00
Industry-Specific
Parameter Application
00: Disabled
01: User-defined parameter
02: Compressor
03: Fan
04: Pump
05: Conveyor
06: Machine tool
07: Packing
08: Textiles
10: Logistics
11: Tension PID
12: Tension PID + master / auxiliary frequency
00
13-01
13-50
Application Parameters
(User-Defined)

Table of Contents

Other manuals for Delta VFD11AMS23ANSAA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD11AMS23ANSAA and is the answer not in the manual?

Delta VFD11AMS23ANSAA Specifications

General IconGeneral
Input Voltage200-240V AC
Output Voltage0-240V AC
Frequency Range0-400 Hz
Protection ClassIP20
Communication InterfaceRS-485
AltitudeUp to 1000 m
Output Current10 A
Control MethodV/F Control
Protection FeaturesOvervoltage, Short Circuit
Cooling MethodFan Cooling
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Humidity90% RH, non-condensing