Chapter 13 Warning CodesMS300 
496 
 
Warning Setting Parameter 
Pr.14-74 Over-torque Detection Selection (Motor 3) = 1 or 3 
0: No function 
1: Continue operation after over-torque detection during constant speed 
operation 
2: Stop after over-torque detection during constant speed operation 
3: Continue operation after over-torque detection during RUN 
4: Stop after over-torque detection during RUN 
When the output current < Pr.14-75, the Ot3 warning automatically clears 
When the output current < Pr.14-75, the Ot3 warning automatically clears 
Incorrect parameter setting 
Configure the settings for Pr.14-75 and Pr.14-76 again. 
Mechanical error (e.g. mechanical 
lock due to over-torque) 
Remove the causes of malfunction. 
Decrease the loading. 
Replace with a motor with larger capacity. 
Accel. / Decel. time and working 
cycle is too short 
Increase the setting values for Pr.01-12–01-19 (accel./ decel. time) 
Adjust the V/F curve (Motor 3, Pr.01-54–01-61), especially the setting value for 
the mid-point voltage (if the mid-point voltage is set too small, the load capacity 
decreases at low-speed). 
The motor capacity is too small 
Replace with a motor with larger capacity. 
Overload during low-speed 
operation 
Decrease the loading during low-speed operation. 
Increase the motor capacity. 
The torque compensation is too 
large 
Adjust the torque compensation value (Pr.07-73 torque compensation gain) 
until the output current decreases and the motor does not stall. 
Improper parameter settings for 
the speed tracking function 
(including restart after momentary 
power loss and restart after fault) 
Correct the parameter settings for speed tracking. 
Start the speed tracking function. 
Adjust the maximum current for Pr.07-09 speed tracking.