Chapter 12 Descriptions of Parameter SettingsMS300 
315 
 
 Crane application example: 
 
 It is recommended that you use this with the Dwell acceleration/deceleration function as shown 
in the following diagram. 
   
External Operation Control Selection after Reset and Reboot 
1: Drive runs if the RUN command remains after reset or reboot.   
Setting value as 1: Pay attention that the drive will execute the running command by itself in the 
following status. 
 Situation 1: After the drive is powered on and the external terminal for RUN stays ON, the drive 
runs. 
  Situation 2: After clearing a fault once a fault is detected and the external terminal for RUN stays   
ON, you can run the drive by pressing the RESET key.   
 Use this parameter with MO = 43 and set Pr.10-00 = 5. 
 Use this parameter to set the motor’s speed level at zero-speed. When the actual speed is lower 
than this setting, the corresponding multi-function output terminal setting 43 is ON, as shown in 
the diagram below.