Chapter 12 Descriptions of Parameter SettingsMS300 
350 
 
Induction Motor (IM) or Permanent Magnet Synchronous AC Motor 
Selection 
1: SPM (Surface permanent magnet synchronous AC motor) 
2: IPM (Interior permanent magnet synchronous AC motor) 
Full-load Current for a Permanent Magnet Synchronous AC Motor 
Default: Depending on the 
model power 
0–120% of the drive’s rated current 
Rated Power for a Permanent Magnet Synchronous AC Motor 
Default: Depending on the 
motor power 
 Sets the rated power for the permanent magnet synchronous AC motor. The default is the drive’s 
power value. 
Rated Speed for a Permanent Magnet Synchronous AC Motor 
Number of Poles for a Permanent Magnet Synchronous AC Motor 
Stator Resistance for a Permanent Magnet Synchronous AC Motor 
Permanent Magnet Synchronous AC Motor Ld 
Permanent Magnet Synchronous AC Motor Lq 
Ke parameter of a Permanent Magnet Synchronous AC Motor 
 When using Delta MSI Motor, set Pr.05-51 according to the corresponding setting value in the 
table below to complete motor auto-tuning.