Chapter 16 PLC Function ApplicationsMS300
706
Classification
API
Command Code
P
Command
Function
STEPS
16 bit
32 bit
16 bit
32 bit
138
DTANH
Find the hyperbolic tangent of
a binary floating point number
9
Calendar
160
TCMP
Compare calendar data
11
161
TZCP
Compare calendar data range
9
162
TADD
Calendar data addition
7
163
TSUB
Calendar data subtraction
7
166
TRD
Calendar data read
3
GRAY Code
170
GRY
DGRY
Convert BIN to GRAY code
5
9
171
GBIN
DGBIN
Convert GRAY code to BIN
5
9
Data Processing
202
SCAL
DSCAL

Scale value operation
5
9
Contact Form
Logical
Operation
215
LD&
DLD&
-
Contact form logical operation
LD#
5
9
216
LD|
DLD|
-
Contact form logical operation
LD#
5
9
217
LD^
DLD^
-
Contact form logical operation
LD#
5
9
218
AND&
DAND&
-
Contact form logical operation
AND#
5
9
219
ANDl
DANDl
-
Contact form logical operation
AND#
5
9
220
AND^
DAND^
-
Contact form logical operation
AND#
5
9
221
OR&
DOR&
-
Contact form logical operation
OR#
5
9
222
OR|
DOR|
-
Contact form logical operation
OR#
5
9
223
OR^
DOR^
-
Contact form logical operation
OR#
5
9
Contact Form
Comparison
Command
224
LD=
DLD=
-
Contact form compare LD*
5
9
225
LD>
DLD>
-
Contact form compare LD*
5
9
226
LD<
DLD<
-
Contact form compare LD*
5
9
228
LD<>
DLD<>
-
Contact form compare LD*
5
9
229
LD<=
DLD<=
-
Contact form compare LD*
5
9
230
LD>=
DLD>=
-
Contact form compare LD*
5
9
232
AND=
DAND=
-
Contact form compare AND*
5
9
233
AND>
DAND>
-
Contact form compare AND*
5
9
234
AND<
DAND<
-
Contact form compare AND*
5
9
236
AND<>
DAND<>
-
Contact form compare AND*
5
9
237
AND<=
DAND<=
-
Contact form compare AND*
5
9
238
AND>=
DAND>=
-
Contact form compare AND*
5
9
240
OR=
DOR=
-
Contact form compare OR*
5
9
241
OR>
DOR>
-
Contact form compare OR*
5
9
242
OR<
DOR<
-
Contact form compare OR*
5
9
244
OR<>
DOR<>
-
Contact form compare OR*
5
9
245
OR<=
DOR<=
-
Contact form compare OR*
5
9
246
OR>=
DOR>=
-
Contact form compare OR*
5
9
Floating Point
Contact Form
275
-
FLD=
-
Floating point number contact
form compare LD*
-
9
276
-
FLD>
-
Floating point number contact
form compare LD*
-
9
277
-
FLD<
-
Floating point number contact
form compare LD*
-
9

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD2A7MS43ANSAA and is the answer not in the manual?

Delta VFD2A7MS43ANSAA Specifications

General IconGeneral
BrandDelta
ModelVFD2A7MS43ANSAA
CategoryDC Drives
LanguageEnglish

Related product manuals