EasyManuals Logo
Home>Delta>DC Drives>VFD4A8MS23ANSAA

Delta VFD4A8MS23ANSAA User Manual

Delta VFD4A8MS23ANSAA
805 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #521 background imageLoading...
Page #521 background image
Chapter 13 Warning CodesMS300
512
ID No.
Display on LCD Keypad
Warning Name
Description
54
PLC buffer overflow
(PLor)
PLC register overflow
Action and Reset
Action Condition
When PLC runs the last command and the command exceeds the maximum
capacity of the program, then PLor warning occurs.
Action Time
Immediately act when the fault is detected
Warning Setting Parameter
N/A
Reset Method
Check if the program is correct and download the program again. If the fault
does not exist, the warning automatically clears.
Reset Condition
N/A
Record
N/A
Cause
Corrective Actions
The program detects internal
source code error during PLC
operation
1. Disable PLC
2. Reset the PLC program (Pr.00-02 = 6)
3. Enable PLC
4. Re-download the PLC program

Table of Contents

Other manuals for Delta VFD4A8MS23ANSAA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD4A8MS23ANSAA and is the answer not in the manual?

Delta VFD4A8MS23ANSAA Specifications

General IconGeneral
BrandDelta
ModelVFD4A8MS23ANSAA
CategoryDC Drives
LanguageEnglish

Related product manuals