Chapter 16 PLC Function Applications│CP2000 
 
16-55
 
Classification  API 
Command code   
P 
command 
Function 
STEPS 
16 bit  32 bit  16bit  32bit 
Floating point 
contact form 
275  – 
FLD= 
– 
Floating point number contact 
form compare LD
※  
–  9 
276  – 
FLD> 
– 
Floating point number contact 
form compare LD
※  
–  9 
277  – 
FLD< 
– 
Floating point number contact 
form compare LD
※  
–  9 
Compare 
command   
278  – 
FLD<> 
– 
Floating point number contact 
form compare LD
※  
–  9 
279  – 
FLD<= 
– 
Floating point number contact 
form compare LD
※  
–  9 
280  – 
FLD>= 
– 
Floating point number contact 
form compare LD
※  
–  9 
281  – 
FAND= 
– 
Floating point number contact 
form compare AND
※  
–  9 
282  – 
FAND> 
– 
Floating point number contact 
form compare AND
※  
–  9 
283  – 
FAND< 
– 
Floating point number contact 
form compare AND
※  
–  9 
284  – 
FAND<> 
– 
Floating point number contact 
form compare AND
※  
–  9 
285  – 
FAND<= 
– 
Floating point number contact 
form compare AND
※  
–  9 
286  – 
FAND>= 
– 
Floating point number contact 
form compare AND
※  
–  9 
287  – 
FOR= 
– 
Floating point number contact 
form compare OR
※  
–  9 
288  – 
FOR> 
– 
Floating point number contact 
form compare OR
※  
–  9 
289  – 
FOR< 
– 
Floating point number contact 
form compare OR
※  
–  9 
290  – 
FOR<> 
– 
Floating point number contact 
form compare OR
※  
–  9 
291  – 
FOR<= 
– 
Floating point number contact 
form compare OR
※  
–  9 
292  – 
FOR>= 
– 
Floating point number contact 
form compare OR
※  
–  9 
Driver special 
command   
139  RPR  – 
 
Read servo parameter  5  – 
140  WPR  – 
 
Write servo parameter  5  – 
141  FPID  – 
 
Driver PID control mode  9  – 
142  FREQ  – 
 
Driver torque control mode  7  – 
261  CANRX  – 
 
Read  CANopen  slave  station 
data   
9  – 
264  CANTX  – 
 
Write  CANopen  slave  station 
data   
9 
– 
265  CANFLS  – 
 
Refresh  special 
D corresponding to CANopen   
3 
– 
320  ICOMR  DICOMR 
 
Internal communications read    9  17 
321  ICOMW  DICOMW 
 
Internal communications write    9  17 
323  WPRA  –  –  RAM write in drive parameters  5  –