Series | VFD-A |
---|---|
Enclosure Rating | IP20 |
Power Range | 0.4kW-22kW |
Control Mode | V/F Control, Sensorless Vector Control |
Overload Capacity | 150% for 60 seconds |
Communication | RS-485 |
Protection Features | Overvoltage, Undervoltage, Overcurrent, Overload, Overtemperature, Short Circuit |
Cooling Method | Fan cooling |
Operating Temperature | -10°C to +50°C |
Storage Temperature | -20°C to +60°C |
Humidity | 90% RH, non-condensing |
Provides specific information to unpack, install, and operate the AC drive.
Details procedures for receiving, storing, and transporting the AC drive.
Explains the details found on the AC drive's nameplate.
Identifies drive components and describes removal/installation procedures.
Specifies environmental and spatial requirements for installing the AC drive.
Details main circuit and control circuit wiring connections for the AC drive.
Illustrates the fundamental wiring connections for the AC drive.
Details the parts and functions of the digital keypad interface.
Explains displayed messages and indicators on the digital keypad.
Describes how to use the keypad for operation and programming.
Steps for initial operation before connecting the motor.
Guides connecting the motor and performing initial operations.
Configures the source for the AC drive's operating frequency.
Determines the source for AC drive operating instructions.
Defines how the motor stops when a stop command is received.
Sets maximum/minimum frequency, voltage, and mid-point values.
Illustrates standard, custom, and fan/pump V/F curve configurations.
Sets the main acceleration and deceleration times (Time 1).
Configures alternate accel/decel times and jog times.
Configures stall prevention for over-voltage and over-current conditions.
Sets DC braking current, start-up, stopping times, and starting frequency.
Configures drive behavior after a momentary power loss.
Sets allowable power loss duration and base block time.
Sets the maximum and minimum reference frequency values.
Selects control wiring modes for external terminals.
Configures function for multi-function input terminals 1, 2, and 3.
Adjusts analog output gain for frequency or current signals.
Assigns functions to multi-function output terminals MO1 and MO2.
Sets analog input voltage levels for frequency range.
Configures desired frequency attained setting.
Sets motor rated and no-load current for protection.
Configures auto torque compensation for initial starting torque.
Compensates for nominal slip to maintain speed under load.
Configures relay outputs for various operational indicators.
Adjusts thermal characteristics based on motor type and temperature.
Sets the time for I²t electronic thermal protection to activate.
Selects how the drive responds to detected over-torque conditions.
Sets the detection level and time for over-torque faults.
Sets the value for the internal counter's countdown.
Determines the initial value for the internal counter.
Selects what monitored item is displayed on the keypad.
Sets a multiplier for user-defined setting display.
Defines three frequencies to be skipped during operation.
Sets the frequency range to be skipped around the skip points.
Sets the carrier frequency for PWM output.
Configures automatic reset or restart after a fault condition.
Stores records of the three most recent faults.
Controls parameter access and allows factory reset.
Sets the communication baud rate for RS-485 interface.
Specifies the bus address for remote control via RS-485.
Lists common failure types like over-voltage, overload, and communication errors.
Details specific faults and their corresponding solutions.
Details electrical and operational characteristics for 230V models.
Details electrical and operational characteristics for 460V models.
Explains how to control the drive using a PC via RS-485.
Details the communication data format, baud rates, and protocol structure.
Provides dimensional drawings for various VFD-A/H drive models.
Shows dimensions for LC-A05E and LC-A10E digital keypads.
Lists remote control box, digital keypads, and extension cables.
Lists braking resistors and EMI core accessories with their applications.
Provides a table matching AC motor drives to suitable EMI filters.
Declares conformity with Low Voltage Directive 73/23/EEC.
Declares conformity with EMC Directive 89/336/EEC.
Provides recommended breaker ratings based on drive input/output current.
Lists recommended fuse types and ratings for AC drives.