304
8.35 Devicemonitor(capability_peripheral_c<0~(n1)>_
devicemonitor_support>0)
Note:Thisre questrequiresAdministratorprivileges.
Method:GET/POST
Synta x:
http://<servername>/cgibin/admin/devicemonitor.cgi
PARAMETER VALUE DESCRIPTION
N/A N/A Returnastatusoverviewofallsensorsandperipheraldevices
oncamera.
Response:
devicemonitor_tempsensor_iX_name:thenameof
temp eraturesensor
devicemonitor_tempsensor_iX_celsius:CurrentCelsius
temp eratureofthesensor
devicemonitor_tempsensor_iX_fahrenheit:Current
fahrenheittemperatureofthesensor
devicemonitor_heater_iY_name:thenameofheatersensor
devicemonitor_heater_iY_status:Currenton/offstatusofthe
heatersensor
X:0~
(capability_peripheral_c<0~(n1)>_devicemonitor_tempnum
1)
Y:0~
(capability_peripheral_c<0~(n1)>_devicemonitor_heaternum
1)
Example: