FOR MODELS:
1DMC5K
MECHANICAL
WINDOW AIR CONDITIONER
USER MANUAL
Before using your air conditioner, please read this manual carefully and
keep it for future reference, along with your receipt. Specifications and
performance data is subject to change without notice.
Question and Answer IconNeed help?

Do you have a question about the DENALI AIRE 1DMC5K and is the answer not in the manual?

Summary

Introduction to Refrigerants R32

Warnings

Important safety warnings and precautions related to refrigerant handling and appliance use.

Important Safety Instructions

Basic Precautions

Essential safety measures to reduce risks of fire, shock, or injury during operation.

FCC Compliance

Details on FCC rules compliance for the device and potential interference.

Electrical Requirements

Electrical Shock Hazards

Precautions to prevent electrical shock, including grounding and outlet usage.

Grounding Method

Guidelines for proper grounding to ensure personal safety and compliance.

LCDI Power Cord

Explanation of the LCDI cord function, testing, and safety features.

Installation Hardware Included

Tools Needed

List of tools required for the installation and assembly process.

Installation & Assembly Instructions

Top Rail Assembly

Instructions for assembling the top rail component onto the air conditioner unit.

Attaching Top Rail to Unit

Step-by-step guide for securing the top rail to the air conditioner.

Accordion Panel Installation

Guidance on how to install the expandable accordion panels on the sides of the unit.

Storm Window Requirements

Necessary adjustments for storm windows to ensure proper unit drainage and function.

Placing Unit in Window

Steps for positioning and securing the air conditioner within the window opening.

Frame Lock, Sash Lock, Foam Seal

Instructions for installing frame locks, sash locks, and foam seals for security and insulation.

Removing Unit from Window

Procedures for safely disconnecting and removing the air conditioner from the window.

Refrigerant R32 Safety

Safety information and requirements for handling R32 refrigerant during installation.

Room Area and Charge Limits

Calculations and tables for maximum refrigerant charge based on room area.

Site Safety

Guidelines for selecting a safe installation location, avoiding hazards.

Operation Safety

Safety measures during operation, including static electricity and protective gear.

Installation Safety

Specific safety checks and procedures during the installation process.

Using Your Air Conditioner

Operating Controls

Explanation of how to use the power, cooling, fan modes, and thermostat controls.

Normal Operating Sounds

Descriptions of expected sounds during normal operation and their causes.

Care and Maintenance

Air Filter Cleaning

Instructions for cleaning the air filter to maintain airflow and efficiency.

Cabinet Cleaning

Methods for cleaning the air conditioner cabinet and front panel safely.

Winter Storage

Guidance on proper storage procedures for the off-season.

Troubleshooting

Unit Will Not Start

Solutions for common issues when the air conditioner fails to power on.

Unit Not Cooling Properly

Troubleshooting steps when the air conditioner does not cool effectively.

Unit Freezing Up

Steps to resolve issues where the air conditioner coils freeze over.

Water Dripping Outside

Explanations and solutions for water dripping from the exterior of the unit.

Water Dripping Inside Room

Causes and fixes for water dripping within the room from the air conditioner.

Water in Base Pan

Information about normal water collection in the base pan and drainage.

Overview

This document is a user manual for a Denali Aire Mechanical Window Air Conditioner, specifically for model 1DMC5K. It provides comprehensive information on installation, operation, maintenance, and troubleshooting.

Function Description

The Denali Aire Mechanical Window Air Conditioner is designed to cool a room by drawing in warm air, removing heat and humidity, and then circulating cooler air. It features mechanical controls for setting temperature and mode. The unit uses R32 refrigerant, which is an environmentally friendly hydrocarbon.

Important Technical Specifications

Model: 1DMC5K Refrigerant: R32 (environmentally friendly hydrocarbon) Electrical Requirements:

  • Voltage: 115 volt (103 min.-127 max)
  • Amps: 0-8 amps
  • Fuse/Circuit Breaker: 10-amp time-delay fuse or circuit breaker
  • Circuit: Use on a single outlet circuit only Window Dimensions for Installation:
  • Width: 23" to 36" (584 mm to 914 mm)
  • Lower Sash Vertical Clearance: 14 1/2" min (368mm) Unit Operation Limits:
  • Outdoor Side: 61~110°F, 80%RH
  • Indoor Side: 61~90°F, 80%RH Refrigerant Charge and Minimum Room Area (for R32, LFL = 0.306 kg/m³): The manual provides detailed tables (GG.1 and GG.2) for maximum charge and minimum room area based on capacity (Btu), installation height (h₀), and charge amount (M). For example:
  • For <9K BTU, room area above 4m²
  • For <12K BTU, room area above 4m²
  • For <18K BTU, room area above 15m²
  • For <24K BTU, room area above 25m² The maximum charge (mmax) and minimum room area (Amin) calculations are based on formulas involving LFL, installation height (h₀), and room area (A).

Usage Features

Controls: The air conditioner uses a mechanical dial for operation.

  • Power: Turn on the unit by rotating the mode dial to the desired setting.
  • Cooling Mode: Set the mode dial to "Snow Flake" for maximum cooling. In high cool mode, the fan automatically goes to high for better air circulation. In "Snow Flake" mode, the fan operates on low.
  • Fan Mode: Choose either of the "Fan" options for fan-only operation. The unit will not cool the room in fan mode.
  • Thermostat: Turn the temperature dial to set the desired room temperature. For maximum cooling, set the dial to 7 (Max Cool).
  • Directional Louvers: Adjust the horizontal wheel to control horizontal airflow and the air deflector to control vertical airflow. Safety Precautions:
  • Always plug into a grounded 3-prong outlet.
  • Do not remove the ground prong or use a plug adapter or extension cord.
  • Unplug the unit before servicing.
  • Use two or more people to move and install the air conditioner due to its weight.
  • The unit is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug for electrical shock protection. Users should test the plug regularly using the TEST and RESET buttons.
  • A 3-minute delay prevents the compressor from overheating and tripping the circuit breaker when changing modes. Normal Operating Sounds:
  • Pinging noise from water hitting the condenser (especially on rainy or humid days) is normal and helps improve efficiency.
  • Thermostat clicking when the compressor cycles on and off is normal.
  • Water collection in the base pan and dripping from the outside is normal due to humidity removal.
  • The fan may run even when the compressor is off.

Maintenance Features

Air Filter Cleaning:

  • Check the air filter monthly for trapped particles and dust.
  • Remove the filter by sliding it out from the front right side.
  • Wash the filter with liquid dish soap and warm water, rinse thoroughly, and gently shake off excess water.
  • Allow the filter to dry completely before reinserting.
  • Alternatively, vacuum the filter to remove dust and particles. Cabinet Cleaning:
  • Unplug the air conditioner before cleaning.
  • Dust the cabinet and front panel with an oil-free cloth or wash with a cloth dampened in a solution of warm water and mild liquid soap.
  • Rinse thoroughly with a damp cloth and wipe dry.
  • Do not use harsh cleaners, wax, or polish on the cabinet front.
  • Wring excess water from the cloth before wiping around controls to prevent damage. Winter Storage:
  • For extended storage, remove the unit from the window according to installation instructions.
  • Cover it with plastic or place it in its original box. Refrigerant R32 Specific Maintenance:
  • Maintenance personnel must strictly comply with the Operation Manual provided by the manufacturer. Non-professionals are prohibited from maintaining the air conditioner.
  • A leak test must be performed after installation.
  • Safety inspections are required before maintenance or repair to minimize fire risk.
  • The handling, installation, storage, servicing, and disposal must comply with gas-related national laws and regulations and national wiring regulations.
  • Refrigerant must be cleared from the system when maintaining or scrapping the unit.
  • The installation site should be well-ventilated and free from open flames, welding, smoking, drying ovens, or any heat source above 548°C.
  • Appropriate anti-static measures (e.g., anti-static clothing/gloves) must be taken during installation.
  • The installation site should be convenient for maintenance, with clear air inlets/outlets, away from heat sources or combustible/explosive environments.
  • If refrigerant leaks during installation, personnel must evacuate for 15 minutes. Damaged products must be returned to a maintenance station; welding refrigerant pipes or other operations on-site are prohibited.
  • Ensure even inlet and outlet air for the indoor unit.
  • Avoid placing the unit near electrical products, power switches, sockets, kitchen cabinets, beds, sofas, or other valuables, and prevent mechanical damage.