bio.x C500 135147 Page 9 of 12 07/2008
9. Optional Accessories
Accessories
Description Item number
Residual current device
adapter
Adapter for fuse protection for the appliance
Release current: 30 mA,
Protection category: IP44
177335
Protective gloves
(1 pair)
with extra long gauntlet, internally padded with cotton fabric
Length: 640mm
Size: 10
EN388: 4121
Resistance: good protection against detergents, alkali, oils and
greases
163613
Filter The additional fine filter can be installed between the pump and runback.
161718
Filter screen type 454
Fineness 80 μm
Can be used as an alternative for filter screen (12) 161047
Perforated metal insert
To protect the work surface of the cleaning table
Makes it possible to work without tilting
152605
Dolly For portable use of the parts cleaning unit 154288
Curved wash brush
For cleaning curved edges, prevents signs of fatigue when working for a
long time.
172560
Stainless steel brush To remove heavily crusted dirt from insensitive parts 173926
Wet vacuum cleaner
Type SV 6.16
To completely empty the tank, also suitable for sludge 123224
Fine filter (14)
The optional fine filter, which can be fitted on the left-hand side of the unit, should be checked weekly and
cleaned if necessary. Release the filter cover by turning it anti-clockwise. Remove the filter cartridge and rinse
it thoroughly under running water, or replace it with a new cartridge. Reinsert the cartridge and screw the cas-
ing firmly back into place. Ensure the seal is in the correct position.
A fine filter retrofit should be carried out in accordance with fitting instructions 135149_DE_DE_BA_100.
Draining device
Used detergent can be let straight out via the ball stopcock underneath the tank.
A draining device retrofit should be carried out in accordance with fitting instructions 135151_DE_DE_BA_100.
Lid (17)
Closing the lid reduces loss of detergent due to evaporation, saves on heating costs and prevents the basin
from getting dirty unnecessarily.
Two M8 screw threads are provided on the unit to retrofit a lid. Attach the lid using the socket cap
screws supplied in the accessory kit. Warning: Do not tighten the screws too much as the user must
be able to open the lid easily.